Difference Between Venturimeter and Orifice Meter

Venturimeter Orifice meter
Losses are very ow and hence, coefficient of discharge (Cc) is high. In general, Cd = 0.98. Losses are high and hence, coefficient of discharge (Cd) is less. In general, Cd =  0.64
Suitable for measurements of higher flow rates. Not suitable for measurements of higher flow rates.
Cost of installation and replacement is more. Cost of installation and replacement is less.
More space is required. Less space is required.
They can be used to measure flow rates of all incompressible fluids (gases with low variations in pressure as well as liquids). They are generally used to measure flow rates of liquids.
Here, the flow is accelerated gradually in converging section with subsequent gradual decrease in pressure. Here, the entire pressure drop occurs instantly, when flow passes through orifice.

Leave a Comment

Your email address will not be published. Required fields are marked *

error: Content is protected !!
Scroll to Top